NAAC Energy Controls Pvt Limited (NECPL) > Activecomp Power Factor Controller

ACTIVECOMP® Controller – Intelligent Power Factor Controller

  • Intelligent Power Factor Controller with master-slave communication
  • 8 steps, expandable up to 24 steps
  • Large graphic display with adjustable brightness
  • Optical Communication Port
  • SMS for triggered alarms
  • Expandable to include features like GPRS/GSM connectivity, ethernet and more
  • Compatible with the NAAC Energy Management System
  • High degree of protection with IP65 rating

Characteristics - ACTIVECOMP® Controller

Product Detail
Series ACTIVECOMP
Model Activecomp Controller
Type Automatic Power Factor Controller
Auxiliary supply
Rated Auxiliary supply voltage Us min 100V AC
max 415V AC
min 110V DC
max 250V DC
Auxiliary operating range 90…484V AC / 93.5…300V DC
Auxiliary rated frequency 50/60 Hz ±10%
Power consumption max 27 VA (with 4 expansion modules)
Power dissipation max 10.5 W (with 4 expansion modules)
5.5 W (with no expansion modules)
Immunity time for microbreakings ≥35 ms (110V AC);
≥80 ms (220…415V AC)
Voltage inputs
Rated Voltage (Ue) phase-phase 600V AC (rated max.)
Operating Voltage range phase-phase 50…720V AC
phase-neutral 415V AC
Frequency range min 45…..65 Hz
max 360…..440 Hz
Type of Measure True RMS value
No-voltage release ≥8 ms
Measurement input impedance phase-phase >1.10 MΩ
phase-neutral >0.55 MΩ
Type of Connection Single phase, two phase, three phase with or without neutral or balanced three phase system
Current Inputs
Number of Current input 3 Nr
Type of Input Shunt supplied by external current transformer (low voltage), Max 5A
Measurement range 0.025…6A ~ for 5A scale
0.025…1.2A ~ for 1A scale
Measurement method True RMS value
Constant overload 1.2 le
Overload peak 50A for 1s
Burden per phase <0.6 VA
Measurement Data
Type of voltage and current measurement True RMS value
Power Factor adjustment 0.5 ind…0.5 cap.
Type of temperature sensor Internal + PT100 with expansion module + NTC with expansion module
Temperature measurement range 0…+212°C
Alarms
Number of Alarms 8
Type of Alarms User programmable
Communication
Communication Port RS-485 (with expansion module)
Communication Protocol Modbus-RTU, ASCII and TCP
Relay Outputs
Number of relay output 8 N° (up to 18 with expansion module)
Contact arrangement 7 NO-SPST + 1 C/O-SPDT
Rated Current 5A 250V AC1
Maximum current at common contact terminal 10A
Maximum switching voltage 415V AC
Electrical life (with rated load) 105 cycles
Mechanical life 30 x 106 cycles
Static Outputs
Number of static output 0 (up to 8 with expansion module)
Insulations
Rated insulation voltage Ui 600 V
Rated impulse withstand voltage Uimp 9.5 kV
Operating frequency withstand voltage 5.2 kV
Connections
Type of Terminal Plug-in, removable
Conductor Cross section min 0.2 mm2
max 2.5 mm2
min 24 AWG
max 12 AWG
Tightening torque max 0.56 Nm
5lbin
Ambient Temperature
Temperature Operating temperature min -20°C
max +70°C
Temperature Storage temperature min -30°C
max +80°C
Relative humidity <80%
Maximum Pollution degree 2
Overvoltage category 3
Measurement category III
Shock resistance 15g
Vibration resistance 0.7g
Housing
Execution Flush mount
Material Polycarbonate
Mounting Flush-mount, 144x144mm (5.67″ x 5.67″)
Degree of Protection IP65 on Front, IP20 terminals
Dimensions (W x H x D) 144mm x 144mm x 53.2mm
Weight 980 Gram
Expansion Slot 4